sphygmomanometer information
Blood pressure is measured in the most basic care of the work. Ensure the accuracy of data is very important, and automatic measurement of the blood pressure measurement method is operated by the same. Charcot use automatic measurement of the sound and vibration (sweep). The measurement of the mercury sphygmomanometer sphygmomanometer and Barometer of sphygmomanometer. in actual operation should take corresponding measures to ensure the accurate measurement.
To test the accuracy of wrist blood pressure. Methods 100 inpatients at the same time wrist sphygmomanometer and desktop applications sphygmomanometer blood pressure measurement. Statistical results, P <0.01, the difference was significant. Sphygmomanometer wrist than desktop sphygmomanometer measured by the value of high blood pressure: systolic 1.2kPa about high pressure, diastolic blood pressure of about 1.1kPa. Conclusion The use of sphygmomanometer wrist when not in a traditional desktop standard sphygmomanometer to measure the actual blood pressure patients.
OMRON wrist to test electronic
sphygmomanometer clinical application. Community Choice crowd and 345 in-patients were using electronic wrist desktop sphygmomanometer mercury sphygmomanometer and blood pressure measurements and blood pressure measured by the value of the analysis. Results: Two sphygmomanometer closely related to blood pressure measurement, electronic blood pressure in reproducible, but the two blood pressure measured blood pressure values from the significant differences.
A study on accuracy of blood pressure monitoring for cardiovascular diseases patients via wrist electronic manometer
[Objective] wrist electronic sphygmomanometer of cardiovascular disease patients to monitor blood pressure accuracy. [Method] and the use of mercury sphygmomanometer wrist electronic sphygmomanometer blood pressure measurement, based on British Hypertension Society (BHS), a right wrist accuracy of the electronic sphygmomanometer. [Results ] two methods of measuring blood pressure are significant differences (P <0.05), and has a linear correlation between (systolic blood pressure: r 0.48, P <0.001; DBP: r 0.57, P <0.001 ). electronic mercury sphygmomanometer with systolic blood pressure, diastolic blood pressure were -0.06 ± margin 2.12kPa, 0.11 ± 1.65kPa. by BHS standards, electronic measurement of systolic blood pressure and diastolic blood pressure were D. [Conclusion] wrist, sphygmomanometer blood pressure measurement of the accuracy of poor, not suitable for use in cardiovascular ward.
The Evaluation of the OMRONHEM-752 model Electrosphygmomanometer
objective: To evaluate the accuracy of the electronic
sphygmomanometer. Method: 0 O M R H E N M - 752 intelligent electronic sphygmomanometer electronic sphygmomanometer and desktop mercury sphygmomanometer two auscultation of the synchronous method studied. Results: O M R H E N 0 M - 752 intelligent electronic devices and desktop mercury sphygmomanometer blood pressure measured by the difference was not statistically significant. Conclusion: 0 O M R H E N M - 752 intelligent electronic sphygmomanometer has good accuracy, can be used for family and the hospital blood pressure monitoring.
Blood pressure measurement is the health screening of students in a technical work a strong sense of responsibility and work. Due to technical standards and accountability, the subjective and objective factors, the result may be large margin. 1,999 students in the annual health check on the wrist in the electronic sphygmomanometer and blood pressure measurements desktop to explore wrist electronic sphygmomanometer student health examination of the feasibility work.
OMRON HEM - 605 wrist-the accuracy of the electronic sphygmomanometer
Objective: To investigate the electronic sphygmomanometer wrist blood pressure measurement accuracy. Methods: At the same time the use of electronic sphygmomanometer wrist and mercury sphygmomanometer blood pressure measurement, based on British Hypertension Society (BHS), a right wrist accuracy of the electronic sphygmomanometer. Results: Measuring blood sphygmomanometer Pressure no significant difference (P> 0.05), but both the standard deviation of the margin pressure in the 15.93mmHg systolic blood pressure, diastolic blood pressure was 12.37mmHg, based on the British standard equipment for the D rating. Conclusion: OMRONHEM - 605 electronic sphygmomanometer wrist measurement of blood pressure accuracy poor, may not be suitable for use in cardiovascular ward.
Column sphygmomanometer electronic sphygmomanometer and blood pressure monitoring and analysis of the values of
To ensure that electronic sphygmomanometer blood pressure measurement accuracy. Methods electronic sphygmomanometer and blood pressure were measured column sphygmomanometer 100 cases, two more. Results of two kinds of blood pressure measurement diastolic blood pressure (P <0.000), pulse pressure (P <0.002) significant difference. Conclusion staff in the use of electronic devices in the course of regular monitoring of electronic sphygmomanometer.
Desktop sphygmomanometer Overhaul
As desktop
sphygmomanometer indication of the table than accurate, convenient to use than the vertical sphygmomanometer, it was the largest clinical use. A sphygmomanometer easy emerging issues translocation machinery parts, deformation, damage, take bubble, and missed mercury, less mercury, such as leakage.